Safety control & I/O

Performance and practicality
for machine control

Modern machine control requires system-wide synchronisation of motion axes with microsecond accuracy. The NX I/O system offers this timing accuracy and repeatability for a wide variety of in- and outputs. Its ultra-fast internal bus system is synchronised with the Distributed Clock of the EtherCAT network, resulting in system-wide deterministic I/O operation.

  • Ideal match with Sysmac Machine automation controllers and CJ2-series PLC’s

  • Synchronous I/O updates, system-wide, with less than 1 μs jitter using EtherCAT

  • High density: up to 16 digital or 8 analog signals in 12 mm width

  • Removable wiring terminals for easy system assembly and testing

Features

  • Networks

    We chose EtherCAT as control network for the Sysmac NJ Machine Controller series. The convenience of standard Ethernet cabling combined with extremely fast on-the-fly data exchange have resulted in a new machine control architecture. The resulting openness, modularity and determinism are the key elements in today’s machine automation.

    • Using open standards for programming and networking assure exchangeability and interoperability with external systems
    • Modularity allows flexibility in system configurations for fast adaptation to end-user requirements
    • Determinism is needed to keep control of the machine while increasing performance and accuracy

    EtherNet/IP uses the CIP protocol over standard Ethernet infrastructure to offer efficient yet reliable data exchange. Using the EtherNet/IP bus coupler, NX-series I/O – including safety control – can be connected to CJ/CS-series PLC’s.

    ProfiNet bus coupler expands NX I/O platform capabilities enabling a wider range of possible architectures.

  • Performance

    Since each set of NX-series I/O’s on an EtherCAT coupler counts as just a single EtherCAT node, the overall network performance is hardly affected by the number of installed I/O units. Keeping the number of EtherCAT nodes to a minimum will help to keep the refresh cycle times of EtherCAT motion axes as low as possible, even at high I/O counts. Furthermore, local fault or damage to an I/O unit will not affect other EtherCAT nodes down the line. The internal bus of the NX-series is fully synchronised with the EtherCAT Distributed Clock. This assures exact timing of any in- or output unit in the control system to within 1 µs, wherever the I/O units are mounted.

  • Design

    For the design of the NX-series, we used our experience in distributed I/O systems combined with customer feedback.

    • The units are compact, with a standard width of 12 mm per unit, yet offer up to 16 channels per unit
    • The front connectors feature toolless push-in wiring with 8 mm ferrules for wire up to 1.5 mm2
    • The terminals are removable to allow pre-wiring and safe step-by-step testing
    • Matching labels on unit and connector reduce the chance of incorrect assembly
    • You can insert 6 keys in the terminal and the unit to mechanically prevent a mismatch
  • Digital I/O Units

    The NX-series let you mix economical standard I/O’s with high-speed synchronous models. The standard digital I/O’s have 16 connections per unit, with a choice of:

    • 3-wire sensor connection with power supply (4-channel units)
    • 2-wire contact inputs or actuator outputs (8-channel-units)
    • 1-wire connection for sensors and actuators already connected to a common power supply (16-channel units)

    High-speed I/O’s all use 3-wire connection, and have On/Off response times of less than 300 ns. Using the EtherCAT Distributed Clock, all inputs can be latched, and outputs can be controlled synchronously, with less than 1 µs jitter.

    For even more control over the exact I/O timing, time-stamp inputs will tell you the exact time of each signal transition. Similarly, time-stamp outputs anywhere in the EtherCAT network can be independently controlled with sub-microsecond accuracy.

  • Analog I/O Units

    Input signals from analog sensors, 4-20 mA transmitters, thermocouples or resistance thermometers can easily be connected and used for monitoring, data logging, trending or PID control. Analog units are offered with sampling times down to 10 µs per channel and high resolution (1:30,000). Built-in filtering, offset correction, broken wire- and overrange detection are all standard functions. The user can select from 12 different thermocouple characteristics, °C/°F and indication resolution down to 0.01 degree. With up to eight inputs in just 12 mm width, the NX-series are among the most compact modules on the market today.

  • High-speed analog input unit

    The High-speed Analog Input Unit allows an up to 5µs sampling rate on analog signals. The fast measuring of analog signals enables an improved quality inspection or a vibration analysis for predictive maintenance. Machine’s Quality and Availability can be improved resulting then in a better OEE (Overall Equipment Effectiveness) rate. This unit can read up to 4 different signals at the same time by keeping the 5µs even if the 4 channels are used. The isolation between channels prevents from distortion between channels.

  • Position I/O Units

    Various types of encoder signals can be connected, from incremental to Synchronous Serial (SSI) encoders. The ability to synchronize the position data with the EtherCAT Distributed Clock means that the encoder can be used as a motion axis for gearing or following. Pulse outputs up to 500 kHz can be used for discrete control or positioning and can also be mapped as a motion axes when used with the Sysmac NJ machine controller.

  • IO-Link Master Unit

    IO-Link makes communication down to the sensor level visible

    • Machine downtime can be reduced.
    • Abnormality detection for shortest recovery.
    • Condition monitoring for predictive maintenance.
    • Individual identification for reduction of man hours.
    • NX I/O Series Master unit with screw-less terminal block or GX Series with IP67 protection class for watery and dusty environments.
    • Up to 4 sensors can be connected with one NX I/O Series IO-Link master unit.
    • Photoelectric and Proximity sensors available.
  • Integrated Safety

    Safety control units and safe in- and output units can be added to any NX-series EtherCAT I/O stations, to fully integrate safety and standard control in one network. The NX-series fulfills all safety Performance Levels from PL a to PL e. Since the standard NJ-series controllers (V1.06 and up) and NX-series bus couplers (V1.1 and up) can be used, standard control and safety can be scaled independently.

  • Temperature Control

    Optimize Control by Detecting Status Changes Easily Satisfy Both Productivity and Quality

    • Adaptive control for self-optimization of control setting due to process changes
    • Specialized function for better sealing application (packaging) and for water-cooled extruders (plastic)
    • Easier integration thanks to ProfiNet, Ethernet-IP and EtherCAT Fieldbus support

Related Products

GI-S Series

GI-S Series

NJ1

Sysmac controller – NJ1 Series

NJ3

Sysmac controller – NJ3 Series

NJ5

Sysmac controller – NJ5 Series

NX Safety Hybrid

From single machine to production line all, safety interconnect

NX Safety distributed

Integrated safety into machine automation

NX1

Information & Productivity in a miniaturized size controller

NX1P

Information & Productivity in a miniaturized size controller

NX7

Sysmac controller – NX7 series

NXR

EtherNet IP IO-Link master and IO-Hub IP67 remote terminals

NY5

IPC Machine Controller

Sysmac Studio

Boost Your Productivity

News

Corporate news, articles & white papers